Leaderboard
we specialize in the design and manufacture of products for monitoring and controlling corrosion

AT ESTIMATOR


EDI Model AT Linear Anode
Materials Quantity and Price Estimator
for Aboveground Storage Tank Bottoms
Enter design parameters in the yellow area – click Estimate Button
Then
Read details, material requirements, and cost estimates below.

Units of Measure
English  

Metric
Tank Diameter
ft.
Anode Spacing
ft.
Ring Wall to Junction Box
ft.
Outer Loop to Ring Wall

ft.
Current Density
mA/sq.ft.  
 OR  Total Current Requirement
Amps

  


Calculated Quantities
  Details
Tank Bottom Area Total Current Requirement
Number of Loops Total Protected Area
Largest Loop Diameter

Anode Length

  Required Materials
50 ft. Anodes

Pin-end & Socket-end lead wires

Tee-end lead wires
Pin-end & Socket-end wire length

Tee-end wire length Recommended Ref Electrodes
(EDI Model US-CUG)


  Estimated Costs: (Suggested Retail Prices)
Pt on Cu cored Ti MMO on Cu cored Ti  
Connector Lead Wires Estimated Man-hours for Installation
Reference Electrodes    


NOTES:
1.Required materials based on a single circuit with a power feed on each end and
intermediate tee feeds as required. Tee-end feeds are recommended every 1,000 ft. (300 m). One reference electrode is recommended for
every 50 feet (15 m) of tank diameter.
2. Pt and MMO perform the same in this application. Choice is based on personal preference.

3. Estimates based on 1/3 man-hr. per anode. Experienced crews should take less time.

4.These calculations are based on protecting only one surface. If two surfaces are being protected, double the desired current density.

Estimator Created by DelWeg Logo